More
Product recommendation

Patient Monitor

Model: RC-PM8000C 12.1" multi-parameter Patient Monitor

Word:[Big][Middle][Small] QR Code 2017-11-8     Viewed:    
Product Name : 12.1" multi-parameter Patient Monitor

Product Model: RC-PM8000C

Product Technical Data:

Application:Adult/Pediatric/Neonatal/Medicine/Surgery/ Operating Room/ICU/CCU


Product Features:

Light & handy

Measurement: ECG/ SpO2/NIBP/HR&PR/Resp

Network: Wire/wireless network & online update

Triplex alarms: Light/Sound (High/medium/low levels adjustable) Electrode Disconnection Alarm (Diagram)

Windows XP Operating System

Easy operation/stable performance

Electrotome/defibrillation tolerance

Restore within 5 seconds after defibrillation

Power Supply: AC & DC Data Storage

Trend diagram/table: 720h

NIBP review: 10000 event

Wave review: 12h

Alarm review: 200 alarm events

Support drug concentration titration analysis


Physical Specification:

Product dimension & weight Equipment: 310mm×150mm×275mm&4kg

Package: 380mm×350 mm×300mm&6kg

Monitor :12” real color TFT screen,  Resolution:800*600

Battery : 11.1V 24wh Li-ion battery,2h operating after full charge(one piece) ,  5min operating after low battery alarm   

Electrical Power : AC: 100 ~ 240V, 50Hz/60Hz,DC: Built-in rechargeable battery


Product Technique Specification:

ECG

  3Leads:     RA, LA, LL

  Lead mode:  I, II, III

  5 Leads: RA, LA, LL, RL, V

  Lead mode: Ⅰ,Ⅱ, Ⅲ, AVR, AVL, AVF, V

Resp

Method: impedance between RA-LL Resp Impedance range: 0.3 ~ 3Ω

Base Impedance range: 200Ω ~ 4000Ω

Bandwidth: 0.3 ~ 2.5Hz

Battery

11.1V 24wh Li-ion battery

   2h operating after full charge(one piece)

   5min operating after low battery alarm

 AC and Drift tolerance

Segment Range:

-2.0mV ~ +2.0mV (accuracy 0.02mV)


Heart/Pulse Rate

Measure range: Adult 15 ~ 300 bpm Neonatal/Pediatric  15 ~ 350 bpm Accuracy: ±1%      Resolution:        1 bpm


NIBP

Method: Oscillometry

Measure mode: Manual, Auto, STAT Measure


Heart/Pulse Rate

Measure range:

Adult 15 ~ 300 bpm Neonatal/Pediatric 15 ~ 350 bpm   Accuracy: ±1%       Resolution: 1 bpm

Optional: Temp

Channel 2

Measure & alarm range 0 ~ 50°C Resolution 0.1°C

    Accuracy (no sensor) ± 0.1°C (0~50°C

Support heart Pace-making Analysis

13 Arrhythmia Analysis:

Asystole, V-Fibrillation/Tachycardia, Single/Paired/Multiform PVC, Bigeminy, Trigeminy, Polycardia, P-0N-T, Bradycardia, Leaky-wave, Pacemaker

not captured, Pacemaker failure

SpO2

Measurement range: 0 ~ 100%

Resolution: 1%

Accuracy: 70% ~ 100% ±2%

              40% ~ 69%      ±3%


IBP (optional)

——

EtCO2 (optional)

——


System Inputs & Outputs

NIBP/SpO2/Temp/ECG/IBP Sensor Sockets RJ45 port


Standard Package

Main unit

(12”screen) NIBP

NIBP cuff & tube

ECG cable

SpO2  sensor

Temperature probe

Lithium-ion battery

Optional Accessories: Touch screen, Trolley bracket, Hanging bracket, Monitor recorder, Vehicle-mounted power supply




Go Back
Print
[Upward]