More
Product recommendation

Medical Defibrillator

RC-DM7000 Automatic External Defibrillator

Word:[Big][Middle][Small] QR Code 2022/2/24     Viewed:    

RC-DM7000 Automatic External Defibrillator




Product Description:

* It is a defibrillation device,which can meet your clinical needs from basic lift support to advanced cardiac life support.
* 5 Languages available: English. Russian. Spanish. Chinese, Turkish.
* Itis a compact,durable, light weighted defibrillatorwhich integrated monitoring, manualdeirillation, AED and pacer (option).
* It is a professional biphasic. defibrillator- monitor suitable for hospitals and clinics,with ECG monitoring paddles andCptional SpO2 (Nellcor, Meditech) : NIBP, EtCO2 and PC Software.

Technical specifications:

• Display
Screen Type: High-resolution display
Screen Size: 7 inches (17.7 cm) diagonally
Sweep Speed: 25mm/sec
Information: Heart Rate, Lead/Pads, Alarm On/Off, SpO2, AED Functions and Prompts, Alarm Selection and Limits, Delivered Energy.

• Defibrillator
Waveform: Biphasic
Energy Display: Monitor display indicates both selected and delivered energy.
Charge Prompt Type: Voice and visual prompts
Electrode Impedance Measurement Range: 0-250 ohms.

Charge Time: Less than 7 seconds with a new


• ECG Monitoring
Patient Connection: 3-lead ECG cable, or 5- lead ECG cable. paddles
Lead Selection: Displayed on monitor, paddles,1,ll ll, AVR, AVL, AVF, V
ECG Size: 0.25,0.5, 1, 1.5, 2, 4 cm/mV diplay on monitor
Heart Rate: 20-300BPM
Heart Rate Alarm: On/Off displayed on monitor, user- selectable
Smart Alarms: Beeper/voice prompts indicate shockable rhythm

• Battery
Type: Rechargeable, Ni- MH battery, 12v
Operating Time: For a new, fully charged battery 60 defibrillator discharges at maximum energy, or 3 hours minimum of continuous ECG monitoring Additional parameters will effect operating time with different functions.

• SpO2 Module
Measurement Range: 30~ 100%,± 2% between80%~90%, others ±5%
Alarm Range: User set high limit and low limit
Alarm Accuracy:±10% within setting values
Alarm time Accuracy: less than 12 sec

• Recorder
Paper: 50mm thermal
Speed: 12.5mm/sec, 25mm/sec, 50mm/sec.User- selectable 6-second delay
Printing Method: High-resolution, thermal array print head
Print-out Modes: Manual or automatic, user-configurable
On/Off Control: Front panel and paddle
Automatic Function: 9-seconds recording initiated by alarm activation or defibrillator charge or defibrillator discharge

• AED Mode
AED Function: Auto analyze and charge x3 with programmable auto energy level selection, screen prompts, and voice prompts
Shockable Rhythms: Ventricular fibrillation Ventricular tachycardia QRS complex wave duration
Charge Control: Control on device front panel, press key on paddle

• Manual Mode
Energy Selection: Selectable at 2, 5, 7, 10, 20, 30, 50, 70,100, 150, 200, 300, 360 joules

Synchronized Mode: Synchronizes defibrillator pulse to patient's R-wave. "SYNC" message displayed on monitor




Go Back
Print
[Upward]