Product Introduction

  • Product Features

    Upright, RC-V2000B3 ventilator is a multi-functional ventilator. Suitable to be used in departments of internal medicine, surgery, Obstetrician/Gynecology, pediatrics, emergency room and ICU. Including IPPV, SIPPV, SIMV, SIGH, MANUAL, PEEP, IMV, VCV, PCV, PSV, CPAP, Psupp etc. functions and monitoring O2 concentration. High-resolution 10.4" TFT LCD, real-time parameters display, such as pressure/time and flow-speed/time waves etc. Including cart, humidifier, mechanical arm , compressor and manual ventilator.

  • Product Technical Data

    Display mode

    HD 10.4" TFT color LCD display

    Ventilation mode

    IPPV, SIPPV, SIMV, PEEP, MANUAL, SIGH, (IMV, VCV, PCV, PSV, CPAP)

    Ventilation parameters

    Tidal volume of 50 ~ 1500ml (20 ~ 1500ml)

    Frequency 1 ~ 99 times/min

    SIMV frequency 1 ~ 20 times/min

    Absorption ratio of 2:1 to 1:8 call (4:1 ~ 1:8)

    Inspiratory trigger pressure of -1.0 ~ 2.0 kPa

    Flow trigger sensitivity of 1 ~ 8L/min

    PEEP 0 ~ 2.0 kPa

    1.0 ~ 6.0 kPa pressure control

    Support 1 ~ 4 kPa pressure

    Sigh inspiratory time of 1.5 times (70 to 150 adjustable)

    Inspiratory Ping Taiwan 0 ~ 50%

    Oxygen concentration of 21% to 100%

    Ventilation monitoring

    Tidal volume, ventilation, IPPV frequency, SIMV frequency, total respiratory rate, ratio, peak airway pressure, pressure - time waveform, flow rate - the time wave, positive end expiratory pressure, inspiratory trigger pressure

    Ping suction units, oxygen concentration (autonomous breathing frequency, lung compliance, airway resistance, flow rate - volume loops, pressure - volume loops)

    Security Alarm System

    Oxygen concentration range of 21% upper limit set to 100%

    Limit setting range of 10% to 80%

    Airway pressure alarm limit setting range of 0.3 ~ 6.0 kPa

    Lower limit range of 0.2 ~ 5.0 kPa

    Minute ventilation alarm limit setting range 3.0 ~ 30 L/min

    Limit setting range 1.0 ~ 10 L/min

    Respiratory rate alarm limit setting range of 50 to 99 times/min

    Lower limit range of 0 to 50 times/min

    Maximum tidal volume alarm setting range 0 ~ 2000ml

    Lower limit range of 0 ~ 1800ml

    High pressure continued to alarm when the alarm has been higher than 2.5 kPa

    Suffocation alarm input 15s without tidal volume, the sound, light alarm

    Gas source undervoltage alarm

    Power failure alarm

    Intubation off alarm

    Power Supply AC 220V ± 10% 50Hz ± 1Hz